Vascular Intervention: BIOSOLVE-II Trial Establishes Safety and Clinical Performance of World's First Clinically Proven Magnesium Bioresorbable Scaffold

BIOTRONIK Magnesium Scaffold Demonstrates Exceptional Safety, with No Scaffold Thrombosis at Six Months

(PresseBox) (San Francisco, US / Buelach, Switzerland, )
BIOTRONIK, a leading manufacturer of cardio- and endovascular medical technology, has announced results from the BIOSOLVE-II trial investigating the safety and clinical performance of the world’s first clinically proven magnesium-based bioresorbable scaffold at TCT 2015. The bioresorbable scaffold met its primary angiographic endpoint and demonstrated an outstanding safety profile. The announcement of clinical data from BIOSOLVE-II will be accompanied by publication in the prestigious journal The Lancet, further evidence of the quality of these results.

"The results of BIOSOLVE-II confirm that the BIOTRONIK Magnesium Scaffold is both a safe and effective option for treating coronary artery disease (CAD), and establish it as the first clinically-proven magnesium-based bioresorbable scaffold," commented principal investigator of the study Dr. Michael Haude of the Lukaskrankenhaus, Neuss, Germany. "The device’s favorable safety profile, as demonstrated by the lack of any scaffold thrombosis (ST) at six months from implantation, was especially remarkable."

BIOSOLVE-II is a prospective, multi-center, first-in-man trial evaluating the safety and clinical performance of the BIOTRONIK Magnesium Scaffold; 123 patients were enrolled in Germany, Belgium, Denmark, the Netherlands, Switzerland, Spain, Brazil and Singapore. The trial’s primary endpoint was in-segment late lumen loss (LLL) at six months; a LLL of 0.27 ± 0.37 mm was associated with the device. Additionally, a low rate of target lesion failure (3.3%) and a very low rate of myocardial infarction (0.8%) were observed.

The results of BIOSOLVE-II will be used to obtain CE approval for the device.

"The BIOTRONIK Magnesium Scaffold shows advantages over synthetic polymer-based scaffolds as it can be inflated in a single step. It is based on a natural element widely present in the human body, and the magnesium-based properties promote a faster and simpler implantation procedure," commented Dr. Haude. "Additionally, the magnesium is absorbed within 12 months, faster than polymer-based bioresorbable scaffolds, while vasomotion is observed at 6 months. I look forward to this device attaining CE mark, so I can use it in my patients also outside of trials."

"As a global pioneer in magnesium technology in the cardiovascular field, we pride ourselves on being the first company to gain clinical evidence supporting the safety and clinical performance of our magnesium-based scaffold with this ground-breaking trial," commented Dr. Daniel Buehler, BIOTRONIK President, Vascular Intervention. "These highly promising results further establish BIOTRONIK as an innovator, and open a new chapter in the field of vascular intervention."

Website Promotion

Website Promotion

BIOTRONIK

One of the world's leading manufacturers of cardio- and endovascular medical devices, BIOTRONIK is headquartered in Berlin, Germany, and represented in over 100 countries by its global workforce of more than 5,600 employees. Several million patients have received BIOTRONIK implants designed to save and improve the quality of their lives, or have been treated with BIOTRONIK coronary and peripheral vascular intervention products. Since its development of the first German pacemaker in 1963, BIOTRONIK has engineered many innovations, including BIOTRONIK Home Monitoring®; the world's first 4 F-compatible 200 mm peripheral stent; Orsiro, the industry's first hybrid drug-eluting stent; and the world's first implantable cardioverter defibrillators and heart failure therapy devices with ProMRI® technology.

For more information, visit: www.biotronik.com

The publisher indicated in each case (see company info by clicking on image/title or company info in the right-hand column) is solely responsible for the stories above, the event or job offer shown and for the image and audio material displayed. As a rule, the publisher is also the author of the texts and the attached image, audio and information material. The use of information published here is generally free of charge for personal information and editorial processing. Please clarify any copyright issues with the stated publisher before further use. In case of publication, please send a specimen copy to service@pressebox.de.
Important note:

Systematic data storage as well as the use of even parts of this database are only permitted with the written consent of unn | UNITED NEWS NETWORK GmbH.

unn | UNITED NEWS NETWORK GmbH 2002–2024, All rights reserved

The publisher indicated in each case (see company info by clicking on image/title or company info in the right-hand column) is solely responsible for the stories above, the event or job offer shown and for the image and audio material displayed. As a rule, the publisher is also the author of the texts and the attached image, audio and information material. The use of information published here is generally free of charge for personal information and editorial processing. Please clarify any copyright issues with the stated publisher before further use. In case of publication, please send a specimen copy to service@pressebox.de.